Contact Us
CASE STUDIES

Crude-oil-line-image-thumbnail

36ā€ Crude Oil Line Isolated Using Line Stopping

Wellube completed line plugging on a 36ā€150# crude oil line through inline tee to provide isolation during shut down to cold cut and replace the existing section of the pipeline.

Read More
Enclosure Clamp Seals Leak

62ā€ X 4ā€ Tee Enclosure Clamp Seals Leak with Zero Production Loss

Wellube successfully sealed a sea water leak in the Tee branch of a client pipeline using a 62ā€ x 4ā€ Tee enclosure.

Read More
flare-thumbnail

Flare Line Leak Sealed Online with a 24ā€ Large Enclosure Clamp

Wellube successfully repaired a flare line with multiple sections of corrosion using a 2.9m long 24ā€ enclosure clamp, with zero interruption to production.

Read More
Leak Sealed Online

High Pressure Gas Leak Sealed Online with a 42ā€ Enclosure Clamp

Wellube successfully sealed a gas leak on a 42ā€ pipeline operating at 45 bar with a 42ā€ enclosure clamp and zero interruption to production.

Read More
Ring Clamp

Steam Leak on an Exchanger Flange Sealed with a 6-part 2m Ring Clamp

Wellube successfully sealed a steam leak on an exchanger with a 2-meter ring clamp with no interruption to production. Ā 

Read More
Wire Saws

Diamond Wire Saws used for Platform Decommissioning in KSA

Wellube supplied a range of Diamond Wire Saws (16ā€ to 30ā€ and 26ā€ to 60ā€) along with experienced personnel to a major EPC company to complete platform decommissioning in KSA.

Read More
Barrel Split Tee

2ā€ Line Stopping Completed with Barrel Split Tee

Wellube successfully performed 2ā€ hot tap and line stop for an instrument line and nitrogen line to assist the client in repairing of the damaged line.

Read More
Hot tap operation

20ā€ Hot Tap Operation Performed on a Spiral Wound Chilled Water Pipe

Wellube completed a 20ā€ hot tap operation with a customised couple reinforcement solution on a 38ā€ chilled water line for a petroleum refinery in Egypt.

Read More
Chilled Water line Installation Service

Chilled Water Line Isolated Using 16ā€ Single Position Pipe Freezing

Wellube team safely executed qty 2 off 16ā€ Single Position Pipe Freezing to isolate a chilled water line operating at a line temperature between 5.3 degree C to 10.3 degree C and at 5 bar pressure, for a prestigious client to perform their maintenance .activities.

Read More
Valve Flange

On-line Sealing of Wellhead Master Valve Flange Leak

The clamp was successfully installed at the site and a Sealant Compound was injected into the flange cavity

Read More
sticky contact
Popup close

    Open chat
    Got a query?
    Hi,
    We specialise in flow management, valve reliability and onsite pipeline solutions.
    How can we help you?